  • Select the area you would like to search.
  • ACTIVE INVESTIGATIONS Search for current projects using the investigator's name, institution, or keywords.
  • EXPERTS KNOWLEDGE BASE Enter keywords to search a list of questions and answers received and processed by the ADNI team.
  • ADNI PDFS Search any ADNI publication pdf by author, keyword, or PMID. Use an asterisk only to view all pdfs.

Question

Question Posted 05/13/13:
I saw "Axial DTI", "Average DC", and "Fractional Aniso." in describing DTI images. What's the difference between them since the sequence info looks the same? (only difference I saw was z dimension which was the largest in "Axial DTI")

In addition, would "Axial DTI" yield 3D images of FA, MD, RD, and MO when DTIfit from FSL were to be run?

Thank you in advance!
Response posted 10/14/14 by ADNI MRI Core:
Thank you for your question to the ADNI MRI Core.

Yes, Axial DTI is the raw data that is acquired from the scanner. "Average DC", and "Fractional Aniso." are derived series from the Axial DTI sequence created by the scanner during reconstructions. Yes, Axial DTI should be used to yield 3D images of FA, MD, RD, and MO in FSL.


Thanks you

ADNI MRI Core
Go back to list of topics >