The ADIR Lab provided intensity normalized and gradient un-warped T1 image volumes for all ADNI1 and many ADNI2 scans. As MR vendors offered these corrections online as part of the product, ADNI stopped performing its own preprocessing and instead employed the preprocessing performed by vendor product on the scanner. Consequently, no offline T1 image preprocessing is necessary for ADNI3 and ADNI4 images. Siemens scanners may save two variants of 3D scans with and without gradient linearity correction applied (gradwarp).
ADIR Lab QC will select the variant with gradwarp, but if users need to disambiguate these cases, the gradwarp corrected version
of the image will indicate “DIS3D” in the DICOM header field Image Type (0008,0008) for the series.
All 3D T1 images from ADNIs 3 and 4 include an on-scanner non-uniformity correction, this may not fully eliminate non-uniformity. Many volumetric analysis pipelines now include bias field correction, however users not using such a pipeline and performing analysis which may be influenced by non-uniform intensities within the image may wish to apply an additional bias field correction such as N4 (Tustison et al. IEEE TMI 2010, 29(6)).